To Learn More About Our Software, Visit CERDAAC.com

SIMCO Global Calibration

Tektronix Calibration Services

ISO/IEC 17025 Accredited Calibration and Repair Support for Tektronix Oscilloscopes, Current Probes, and Electronic Test Equipment

Accredited Tektronix Calibration Services

SIMCO provides calibration and repair support for Tektronix electronic test and measurement equipment used in aerospace, defense, telecommunications, electronics manufacturing, semiconductor, research, calibration, and industrial environments.

Tektronix instruments are widely used throughout industries where measurement accuracy directly affects product quality, regulatory compliance, research outcomes, and operational performance. From oscilloscopes and differential probes to current probes, high-voltage probes, current amplifiers, and signal integrity accessories, Tektronix instruments are commonly used in applications where reliable measurements are critical to design validation, troubleshooting, production testing, electronics development, and failure analysis activities.

SIMCO helps organizations maintain confidence in their Tektronix equipment through technically sound calibration practices, traceable results, documented measurement uncertainty, and service options designed to support both individual instruments and larger multi-site calibration programs.

Calibration Support for Tektronix Electronic Test Equipment

SIMCO provides calibration services for a broad range of Tektronix instruments used in electrical, electronic, waveform analysis, current measurement, differential measurement, signal integrity, and high-voltage applications.

Our Tektronix calibration services can help your organization:

  • Maintain traceable measurement results
  • Support audit and compliance requirements
  • Reduce the risk of inaccurate measurements
  • Verify instrument performance against applicable specifications
  • Improve calibration program consistency
  • Manage calibration needs across multiple facilities or service areas
  • Reduce downtime through coordinated calibration and repair support

Whether you are managing a single Tektronix TDS3012B Digital Phosphor Oscilloscope, Tektronix TBS2102B Digital Storage Oscilloscope, Tektronix TCPA300 AC/DC Current Probe Amplifier, Tektronix P6015A High-Voltage Probe, or a large population of Tektronix instruments across multiple locations, SIMCO can help support your calibration program with scalable service options.

Request A Quote:

Tektronix Equipment We Calibrate

SIMCO provides calibration services for many Tektronix instrument categories, including:

Oscilloscopes and Waveform Analysis Equipment

  • Digital oscilloscopes
  • Digital storage oscilloscopes
  • Waveform analysis instruments
  • Electronic troubleshooting equipment
  • Design validation instruments

Common Tektronix oscilloscope models calibrated by SIMCO include the Tektronix TDS2012 Digital Storage Oscilloscope, TDS2012B Digital Storage Oscilloscope, TDS2012C Digital Storage Oscilloscope, TDS2014 Digital Storage Oscilloscope, TDS2024B Digital Storage Oscilloscope, TDS3012B Digital Phosphor Oscilloscope, TDS3012C Digital Phosphor Oscilloscope, TDS3014B Digital Phosphor Oscilloscope, TDS3032B Digital Phosphor Oscilloscope, TDS3034B Digital Phosphor Oscilloscope, TDS3034C Digital Phosphor Oscilloscope, TDS3054B Digital Phosphor Oscilloscope, TDS3054C Digital Phosphor Oscilloscope, TBS2102B Digital Storage Oscilloscope, and 2465B Oscilloscope.

Current Probes and Current Measurement Equipment

  • Current probes
  • AC current probes
  • AC/DC current probes
  • Current measurement systems
  • Current probe amplifiers

Common Tektronix current measurement models calibrated by SIMCO include the TCP202 Current Probe, TCP0020 Current Probe, TCP0030 AC/DC Current Probe, TCP0030A AC/DC Current Probe, TCP303 Current Probe, A622 AC/DC Current Probe, and TCPA300 AC/DC Current Probe Amplifier.

Differential Probes and Signal Integrity Equipment

  • Differential probes
  • High-voltage differential probes
  • Active probes
  • FET probes
  • Differential measurement accessories

Common Tektronix differential probe models calibrated by SIMCO include the P5205 High Voltage Differential Probe, TDP1000 Differential Probe, THDP0200 High-Voltage Differential Probe, TAP1500 Active Probe, P6245 Active FET Probe, and ADA400A Differential Preamplifier.

High Voltage Measurement Equipment

  • High-voltage probes
  • High-voltage measurement accessories
  • Power electronics measurement probes

Common Tektronix high-voltage measurement models calibrated by SIMCO include the P6015A High Voltage Probe and THDP0200 High-Voltage Differential Probe.

Probe Power Supplies and Accessories

  • Probe power supplies
  • Probe interface equipment
  • Measurement accessories

Common Tektronix accessory models calibrated by SIMCO include the Tektronix 1103 TekProbe Power Supply.
If your specific Tektronix model is not listed, contact SIMCO to confirm calibration or repair support availability.

Common Tektronix Instruments and Applications

Tektronix Instrument Type Common Applications
Digital Oscilloscopes Waveform analysis, troubleshooting, design validation, and electronics testing
Current Probes Current measurement, power electronics testing, and circuit analysis
Current Probe Amplifiers Probe interfacing and expanded current measurement capability
Differential Probes Floating measurements, power electronics testing, and signal integrity analysis
High Voltage Probes High-voltage circuit measurement and power system testing
Active and FET Probes High-bandwidth measurements and low-loading signal acquisition
Probe Power Supplies Probe interfacing and measurement system support

ISO/IEC 17025 Accredited Calibration for Tektronix Instruments

SIMCO offers ISO/IEC 17025 accredited calibration services for applicable Tektronix instruments, measurement ranges, and parameters.

  • Accredited calibration may include:
  • As-found and as-left measurement data
  • Documented measurement uncertainty
  • Traceability to the International System of Units through national metrology institutes such as NIST or other recognized reference standards
  • Pass/fail statements, where applicable
  • Calibration documentation to support audits, compliance activities, and quality-management requirements

Accredited calibration is often required when measurement results directly affect product acceptance, product validation, compliance testing, regulated manufacturing, or customer quality requirements.

Why Calibrate Tektronix Equipment?

Tektronix instruments are commonly used to verify critical electrical, waveform, timing, current, voltage, and signal integrity parameters. Over time, normal use, environmental exposure, transportation, handling, and frequency of use can affect measurement performance.

Without routine calibration, inaccurate measurements can contribute to:

  • Product quality issues
  • Failed audits
  • Process deviations
  • Incorrect troubleshooting decisions
  • Compliance risk
  • Increased measurement uncertainty
  • False acceptance or false rejection of products or processes

Routine calibration helps verify that Tektronix instruments continue to perform within applicable specifications and remain suitable for their intended use.

For quality-driven organizations, accredited calibration also provides objective evidence of traceability, technical competence, and documented uncertainty to support customer requirements, internal quality systems, and regulatory expectations.

Tektronix Calibration for Regulated and High-Precision Industries

SIMCO supports Tektronix calibration needs across industries where measurement accuracy, documentation, and uptime are critical.

Our Tektronix calibration services support organizations operating in:

  • Aerospace and defense
  • Telecommunications and wireless communications
  • Semiconductor manufacturing
  • Electronics manufacturing
  • Research and development environments
  • Advanced manufacturing
  • Industrial production environments
  • Calibration and metrology operations

SIMCO can help customers align calibration service levels with internal quality requirements, regulatory expectations, customer specifications, and equipment-use criticality.

Service Options for Tektronix Calibration

SIMCO supports calibration programs through flexible service options designed to fit different operational needs.

Available options may include:

  • Service area-based calibration support
  • Onsite calibration support, where available and applicable
  • Pickup and delivery options in supported service areas
  • Multi-site calibration program support
  • Calibration documentation and certificate management
  • Repair coordination for supported instruments
  • Asset-management and compliance support through CERDAAC

Service availability may vary by instrument type, location, accreditation requirements, and specific model.

Tektronix Repair Coordination and Post-Repair Calibration

In addition to calibration services, SIMCO can help coordinate repair support for many Tektronix instruments when repair is available.

Repair support may include:

  • Functional evaluation
  • Repair coordination
  • Component replacement, where available
  • Performance verification
  • Preventive maintenance support
  • Post-repair calibration

Combining calibration and repair support through a single provider can help simplify equipment management, reduce administrative burden, and help return instruments to service with documented performance verification.

Calibration Documentation and Asset Management

For organizations managing large Tektronix equipment populations, calibration documentation and asset visibility are just as important as the calibration event itself.

SIMCO helps customers manage calibration records, certificates, asset history, scheduling, and reporting through CERDAAC, SIMCO’s calibration and asset-management software.

CERDAAC can help teams:

  • Track calibration status
  • Access calibration certificates
  • Manage asset history
  • Support audit readiness
  • Improve visibility across multiple locations
  • Reduce manual administrative work
  • Support more consistent calibration program execution

Frequently Asked Questions About Fluke Calibration Services

Do you calibrate Tektronix oscilloscopes?

Yes. SIMCO provides calibration services for many Tektronix oscilloscopes, including the TDS2000 Series, TDS3000 Series, TDS3000B Series, TDS3000C Series, TBS2000 Series, and other Tektronix oscilloscope platforms. Contact SIMCO with your model number to confirm service availability and calibration options.

Can SIMCO provide ISO/IEC 17025 accredited calibration for Tektronix instruments?

Yes. SIMCO offers ISO/IEC 17025 accredited calibration for applicable Tektronix instruments, parameters, and measurement ranges. Accreditation availability depends on the specific model and required calibration scope.

Do you calibrate Tektronix current probes?

Yes. SIMCO supports calibration for many Tektronix current probes and current measurement systems, including TCP202, TCP0020, TCP0030, TCP0030A, TCP303, A622, and related models.

Do you calibrate Tektronix differential probes?

Yes. SIMCO provides calibration support for many Tektronix differential probes and signal integrity accessories, including the P5205, TDP1000, THDP0200, TAP1500, and P6245 probe families.

Can Tektronix equipment be calibrated onsite?

Onsite calibration may be available for certain Tektronix instruments depending on the equipment type, location, calibration requirements, and service scope. Contact SIMCO to discuss onsite calibration options for your facility.

Do you repair Tektronix instruments?

SIMCO can help coordinate repair support for many Tektronix instruments when repair is available. After repair, calibration can be performed to verify instrument performance before the equipment is returned to service.

What information do I need to request a Tektronix calibration quote?

The most helpful information includes the Tektronix model number, quantity, required calibration level, service location, accreditation requirements, and whether the instrument requires repair or functional evaluation.

Can SIMCO support Tektronix equipment across multiple facilities?

Yes. SIMCO supports calibration programs for organizations managing equipment across multiple facilities or service areas. SIMCO can help coordinate calibration services, documentation, asset tracking, and program support across locations.

Common Tektronix Models Calibrated by SIMCO

SIMCO calibrates many commonly used Tektronix electronic test and measurement instruments, including oscilloscopes, current probes, differential probes, high-voltage probes, current probe amplifiers, and signal integrity accessories.

The list below includes examples of frequently calibrated Tektronix models supported by SIMCO.

  • Tektronix TDS3012B Digital Phosphor Oscilloscope
  • Tektronix TDS2012C Digital Storage Oscilloscope
  • Tektronix TDS3054B Digital Phosphor Oscilloscope
  • Tektronix TCPA300 AC/DC Current Probe Amplifier
  • Tektronix TCP202 Current Probe
  • Tektronix TCP0030A AC/DC Current Probe
  • Tektronix TDS3034B Digital Phosphor Oscilloscope
  • Tektronix TDS2012B Digital Storage Oscilloscope
  • Tektronix P6015A High Voltage Probe
  • Tektronix TDS3012C Digital Phosphor Oscilloscope
  • Tektronix ADA400A Differential Preamplifier
  • Tektronix TDS3014B Digital Phosphor Oscilloscope
  • Tektronix TDS3054C Digital Phosphor Oscilloscope
  • Tektronix TDS3032B Digital Phosphor Oscilloscope
  • Tektronix P5205 High Voltage Differential Probe
  • Tektronix TDP1000 Differential Probe
  • Tektronix TBS2102B Digital Storage Oscilloscope
  • Tektronix THDP0200 High-Voltage Differential Probe
  • Tektronix TCP0020 Current Probe
  • Tektronix TDS2012 Digital Storage Oscilloscope
  • Tektronix 1103 TekProbe Power Supply
  • Tektronix TCP0030 AC/DC Current Probe
  • Tektronix P6245 Active FET Probe
  • Tektronix TAP1500 Active Probe
  • Tektronix A622 AC/DC Current Probe
  • Tektronix TCP303 Current Probe
  • Tektronix TDS2024B Digital Storage Oscilloscope
  • Tektronix 2465B Oscilloscope
  • Tektronix TDS2014 Digital Storage Oscilloscope
  • Tektronix TDS3034C Digital Phosphor Oscilloscope

Tektronix is a trademark of Tektronix, Inc. SIMCO Electronics is not affiliated with, sponsored by, or endorsed by Tektronix, Inc. All product names, company names, trademarks, and registered trademarks are the property of their respective owners. SIMCO Electronics is not affiliated with, sponsored by, or endorsed by the manufacturers referenced on this page.

Need Calibration for [Manufacturer] Equipment?

Ready to Simply Your Calibration Program

Tell us the model number, instrument type, location, and service requirement. SIMCO will help confirm calibration support and route your request.